Log In     My Account       Shopping Cart: Your cart is empty.

Currencies:
     English  



Home >>  5000 Meters Remote Controls >>  4 CH RF Wireless Remote Control Switch 5000M 30A DC 6V 9V 12V 24V Relay Output Two-way Feedback Function Waterproof

Remote Control Blog

4 CH RF Wireless Remote Control Switch 5000M 30A DC 6V 9V 12V 24V Relay Output Two-way Feedback Function Waterproof


Price: Starting at: US $163.00

Add to Cart:   

  • Model: 0020110 (S4PUW-DC12-ANT2 & CC-4)

Please Choose:






















 Manual 
 
   

Application of this high power s Application of this high power s
Package Include:
1 x Receiver: S4PUW-DC12-ANT2
1 x Transmitter: CC-4
1 x User manual

Feature:

Wireless control, easy to install.
Waterproof case with waterproof connectors.
High power, each relay output can work at maximum 30A current.
Super long range, with a transmitter to form a complete set, the working distance can reach 5000m in an open ground.
Feedback function: can let the user know whether he/she had already connect the transmitter and receiver successfully in such a long distance.
Two ways working mode, when the receiver gets the signal of transmitter, it will immediately send a return signal to the transmitter.
America imported chips, which can ensure reliability and assure the high quality of the products.
Relay output, can be used in home automation, such as security system, remote control lights, motors, Doors / Locks / Windows / Blinds / Cars, and various equipment.
It also can be used in agriculture and industry automation, such as long range and high power remote control devices.
Wireless remote control products on land, water and air, especially in a long distance, such as farm, pasture, offshore unmanned operation, field call, remote security alarm, unmanned aerial vehicle, etc.
You can turn on/off the receiver with transmitter (remote control) from any place within a reliable distance; the wireless RF signal can pass through walls, floors and doors.
With characteristics of reverse power protection and over current protection
Reliable control: The transmitter (Encoding) and the receiver (Decoding) use the custom code.
One/several transmitters can control one/several receivers simultaneously.
You can use two or more units in the same place.
 
Receiver Parameters:
Model No. S4PUW-DC06-ANT2 / S4PUW-DC09-ANT2 / S4PUW-DC12-ANT2 / S4PUW-DC24-ANT2
Power Supply (Operating Voltage): DC6V (S4PUW-DC06-ANT2), DC9V±1V (S4PUW-DC09-ANT2), DC12V±1V (S4PUW-DC12-ANT2), DC24V±2V (S4PUW-DC24-ANT2)
Working Frequency: 433.92MHz
Channel: 4CH
Control Modes: Toggle, Momentary, Latched
Output: Relay output (Normally open and normally closed)
Working Voltage Range of Relay: AC110~240V or DC0~28V
Maximum Working Current of Relay: 30A
Static Current: ≤6mA
PCB size: 170mm x 109mm x 18mm
Case size:200mm x 120mm x 53mm
Work with custom code transmitters.
 
External Magnetic Sucker Antenna:
Frequency Range: 300~450MHz
Impedance: 50Ω
Antenna Length: 15cm
Cable Length:5m, we also can offer longer cable, such as10meters, 30meters.
Weight:55g
Anti-interference, waterproof, shielded wire set inside
Magnetic stand design for easy to install

Transmitter:

Control/Transmitter                 

0021060 (CC-1)        

0021061 (CC-2)                

0021062 (CC-4)              

Button                                  

1                      

2                             

4                               

Button Symbol                  

No Symbol              

Big Button,                Small Button                  

A, B, C, D            

Unit Size                              

135mm x 42mm x 25mm                                        

Weight                                   

90g                                                              

Operating Voltage                            

9V (1 x 6F22 -9V battery, can be used for 12 months. Please switch on the control/transmitter when using it and switch it off when you don’t use it)                                                                        

Working Current                               

65 mA/16mA (transmit / receive a signal)                         

Standby Current                              

5μA                                                                 

Operating Frequency                         

433.92MHz                                                        

Transmitting Distance                        

5000m (theoretically)                                           

Operating Temperature                           

-10 ° C to +70 ° C                                                   

Feedback indication                     

Buzzing Sound                                                     

Encoding Type                                     

Custom Code                                                        

 

It has an on / off button on the side.

Modulation Mode               

FSK+LORA                                                      

 
Usage (with the transmitter):
The receiver and transmitter can be used to control both DC0~28V and AC110~240V equipments.
Notice: The receiver is relay output, not DC/AC power output. Initial state of relay output terminals: Terminals A and B are Normally Open; Terminals A and C are Normally Closed.
 
If you want to control a DC12V lamp, do as following:
1) Connect DC12Vpower adapter “+” to terminal “L / +” and Connect DC12V power adapter “-” to terminal “N / -“.
2) Connect Terminal A to the positive pole of the lamp, connect Terminal B to the positive pole of the power supply, and connect both lamp and power supply’s negative pole.
 
If you want to control an AC220V lamp, do as following:
1) Connect DC12Vpower adapter “+” to terminal “L / +” and Connect DC12V power adapter “-” to terminal “N / -“.
2) Connect Terminal A to one side of the lamp, connect Terminal B to the live wire of the power supply, and connect lamp’s another side to power supply’s neutral wire.
 
Setting different control modes (We have set the receiver as Toggle control mode before delivery. If you want to use other control modes, do as following operation):
 
1) Setting control mode Toggle (with transmitter CC-4): Turn on the first bit of the dip switch.
Control mode Toggle: Press -> On; Press again -> Off.
Press button A of the transmitter: Turn on relay1 (connect A and B, disconnect A and C)
Press button A again: Turn off relay 1 (disconnect A and B, connect A and C)
Press button B of the transmitter: Turn on relay2 (connect A and B, disconnect A and C)
Press button B again: Turn off relay 2 (disconnect A and B, connect A and C)
Press button C of the transmitter: Turn on relay3 (connect A and B, disconnect A and C)
Press button C again: Turn off relay 3 (disconnect A and B, connect A and C)
Press button D of the transmitter: Turn on relay 4(connect A and B, disconnect A and C)
Press button D again: Turn off relay 4 (disconnect A and B, connect A and C)
 
2) Setting control mode Momentary (with transmitter CC-4): Turn on the first and the second bits of the dip switch.
Control mode Momentary: Press and hold -> On; Release -> Off.
Press and hold button A of the transmitter: Turn on relay 1 (connect A and B, disconnect A and C)
Release button A: Turn off relay 1 (disconnect A and B, connect A and C)
Press and hold button B of the transmitter: Turn on relay 2 (connect A and B, disconnect A and C)
Release button B: Turn off relay 2 (disconnect A and B, connect A and C)
Press and hold button C of the transmitter: Turn on relay 3 (connect A and B, disconnect A and C)
Release button C: Turn off relay 3 (disconnect A and B, connect A and C)
Press and hold button D of the transmitter: Turn on relay 4 (connect A and B, disconnect A and C)
Release button D: Turn off relay 4 (disconnect A and B, connect A and C)
 
3) Setting control mode Latched (with transmitter CC-4): Turn on the second bit of the dip switch
Control mode Latched: Press -> On, other relays Off; Press another button -> Off.
Such as:
Press button A: Turn on relay 1 (connect A and B, disconnect A and C)
Turn off other relays (disconnect A and B, connect A and C)
Press button B: Turn on relay 2 (connect A and B, disconnect A and C)
Turn off other relays (disconnect A and B, connect A and C)
Press button C: Turn on relay 3 (connect A and B, disconnect A and C)
Turn off other relays (disconnect A and B, connect A and C)
Press button D: Turn on relay 4 (connect A and B, disconnect A and C)
Turn off other relays (disconnect A and B, connect A and C)
 
Input control terminals:
The receiver has four input control terminals, you can connect external devices, sensors, or manual switches to these terminals to control the outputs of receiver.
1) Signal input:
You can connect external devices (with low level output signal) to terminals “COM”, “Signal 1”, “Signal 2”, “Signal 3”, “Signal 4”, the external device’s output signal can control receiver’s four outputs.
When the external device outputs low level signal to terminal “COM” and “Signal 1“, Relay1 works.
When the external device outputs low level signal to terminal “COM” and “Signal 2“, Relay2 works.
When the external device outputs low level signal to terminal “COM” and “Signal 3“, Relay3 works.
When the external device outputs low level signal to terminal “COM” and “Signal 4“, Relay4 works.
 
2) The manual switches:
You can connect four manual switches to terminals “COM”, “Signal 1”, “Signal 2”, “Signal 3”, “Signal 4”, then you can use these manual switches to control the outputs of receiver.
When connect terminals “Signal 1” and “Com”, Relay1 works.. And when disconnect “Signal 1” and “Com”, Relay1 stops outputting.
When connect terminals “Signal 2” and “Com”, Relay2 works. And when disconnect “Signal 2” and “Com”, Realy2 stops outputting.
When connect terminals “Signal 3” and “Com”, Realy3 works. And when disconnect “Signal 3” and “Com”, Realy3 stops outputting.
When connect terminals “Signal 4” and “Com”, Realy4 works. And when disconnect “Signal 4” and “Com”, Realy4 stops outputting.
 
Notice:
The receiver can only pair two different model transmitters, model CC-4 (5000m), CCW-4 (5000m, waterproof).
 
Setting feedback function:
If you want to have a feedback function: Turn on the third bit of the dip switch.
When the receiver gets the signal of transmitter, it will immediately send a return signal to the transmitter. When the transmitter receive the feedback signal of the receiver, the transmitter will exude a buzzing sound like “D~” which means it receive the feedback signal successfully.
 
How to pair the transmitter to the receiver:
1) Press button K1 of receiver for 1- 2 seconds; signal LED on the receiver is on. The receiver enters into status of LEARNING.
2) Press any one button on remote control. If signal LED flashes twice, it means learning is successful.
 
Delete all transmitters:
We have learned remote control to the receiver. If you don’t want the receiver to work with the remote control, you can delete all codes of remote controls, which are stored in the receiver.
Operation: Press and hold the button of receiver until signal LED flashes three times. That means all stored codes have been deleted successfully.
Ask A Question
* Required information

*
*