Log In     My Account       Shopping Cart: Your cart is empty.

Currencies:
     English  



Home >>  DC Power Remote Kits >>  6 CH DC 6/9/12/24V >>  6 Control Modes >>  6 Channel RF Remote Control 6 Transmitters & 1 Receiver DC 6V 9V 12V 24V

Remote Control Blog

6 Channel RF Remote Control 6 Transmitters & 1 Receiver DC 6V 9V 12V 24V


Price: US $65.00

Add to Cart:   

  • Model: 0020293 (S6C-DC06/09/12/24V & 6C-1)

Please Choose:

























This 6 channel rf remote control operates in toggle, momentary, latched and mixed control mode. You can use it to control at most 6 same or different electrical devices. Remote distance is up to 100m. It is applied for light remote control, motor remote control, garage door remote control, gate remote control, etc.
Package Include:
1 x Receiver: S6C-DC06 / S6C-DC09 / S6C-DC12 / S6C-DC24 (6 Channel / 6 Control Modes)
6 x Transmitter: C-1
1 x User manual
 
Feature:
Application: It can be used in industry automation, agriculture automation and home automation, such as factory, house, farm, pasture, vehicle, ship, offshore operation, aerial vehicle, field call, etc. It can remote control equipments on land, water and air, such as remote control lights, sirens, locks, motors, fans, winches, blinds, linear actuators, doors, windows, electric solenoid valves, security alarm, business signs and various devices.
Wireless control, easy to install.
Relay Output: This receiver is relay output, it can be used to operate both DC and AC equipments. The terminals are NO / NC (normally open / normally closed), which serves as a switch. That means you should also connect a separate power supply to equipments.
You can turn on/ off the receiver with transmitter (remote control) from any place within a reliable distance.
Wireless RF signal can pass through walls, floors, doors or windows.
With reverse power protection and over current protection.
Reliable control: The receiver only works with the transmitter which use same code.
One/several transmitters can control one/several receivers simultaneously.
You can use two or more units in the same place.
 
Receiver Parameters:
Model No.: S6C-DC06/S6C-DC09 / S6C-DC12 / S6C-DC24
Channel: 6 CH
6 Control Modes: Latched, Momentary, Toggle, Momentary + Toggle, Momentary + Latched
Power Supply (Operating Voltage): DC6V (S6C-DC06), DC12V±1V (S6C-DC12), DC9V±1V (S6C-DC09), DC24V±1V (S6C-DC24)
Output: Relay output (Normally open and normally closed)
Working Voltage Range of Relay: AC110~240V or DC0~28V
PCB Size: 94mm x 73mm x 20mm
Case Size: 100mm x 80mm x 30mm
Static Current: ≤6mA
Maximum Working Current: 10A / each channel
Working Frequency: 315MHz / 433MHz
Work with Fixed code transmitters.
 
Transmitter:
Model No.: C-1
Channel: 1 CH
Remote Control Distance: 100m / 300ft (theoretically)
Encode: Fixed code by soldering
Unit size: 58mm x 39mm x 16mm
Power Supply: 1 x 23A -12V battery (included, can be used for 12 months)
 
Working Range:
With a transmitter (such as C-1) to form a complete set, the maximum working distance can reach 100M in an open ground.
The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will be hindered by trees, walls or other constructions, and will be interfered by other wireless signals. Therefore, the actual distance may not reach this maximum working distance.
If you want to have a further working range, you can install an external antenna to the receiver, and you also can use a powerful transmitter, such as CB series transmitters.
 
Usage:
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The receiver is relay output, not DC/AC power output. Initial state of relay output terminals: Terminals B and C are Normally Open; Terminals A and B are Normally Closed.
 
Wiring:
If you want to control a DC 12V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “L / +” of INPUT, and connect the negative pole of DC power supply to terminal “N / -” of INPUT.
2) Connect terminal C to the positive pole of DC power supply, connect terminal B to the positive pole of DC lamp, and connect the negative pole of DC lamp to the negative pole of DC power supply.
 
If you want to control an AC 220V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “L / +” of INPUT, and connect the negative pole of DC power supply to terminal “N / -” of INPUT.
2) Connect terminal C to the live wire of AC power supply, connect terminal B to one side of AC lamp, and connect another side of AC lamp to the neutral wire of AC power supply.
 
Setting different control modes:
Setting different control modes: (We have set the receiver in toggle mode before delivery, if you want to use other modes, do as following operation.)
1) Learning Toggle control mode: When the receiver is in the status of LEARNING, press button of the remote control 1.
Control mode Toggle (Channel 1~6): Press -> On; Press again -> Off.
Press button of remote control 1: Turn on relay 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Press button of remote control 1 again: Turn off relay 1 (disconnect B and C, connect A and B), the lamp 1 is off.

Press button of remote control 6: Turn on relay 6 (connect B and C, disconnect A and B), the lamp 6 is on.
Press button of remote control 6 again: Turn off relay 6 (disconnect B and C, connect A and B), the lamp 6 is off.
 
2) Learning Momentary control mode: When the receiver is in the status of LEARNING, press button of the remote control 2.
Control mode Momentary (Channel 1~6): Press and hold -> On; Release -> Off.
Press and hold button of remote control 1: Turn on relay 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Release button of remote control 1: Turn off relay 1 (disconnect B and C, connect A and B), the lamp 1 is off.

Press and hold button of remote control 6: Turn on relay 6 (connect B and C, disconnect A and B), the lamp 6 is on.
Release button of remote control 6: Turn off relay 6 (disconnect B and C, connect A and B), the lamp 6 is off.
 
3) Learning Latched control mode: When the receiver is in the status of LEARNING, press button of the remote control 3.
Control mode Latched (Channel 1~8): Press -> On, other relays Off; Press other button -> Off.
Press button of remote control 1: Turn on relay 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Turn off other relay (disconnect B and C, connect A and B), other lamps are off.

Press button of remote control 6: Turn on relay 6 (connect B and C, disconnect A and B), the lamp 6 is on.
Turn off other relay (disconnect B and C, connect A and B), other lamps are off.
 
4) Learning Momentary (Channel 1~3) + Toggle (Channel 4~6) control mode: When the receiver is in the status of LEARNING, press button of the remote control 4.
5) Learning Momentary (Channel 1~3) + Latched (Channel 4~6) control mode: When the receiver is in the status of LEARNING, press button of the remote control 5.
6) Learning Toggle control mode (Channel 1~4) + All On / Off (Channel 5/6): When the receiver is in the status of LEARNING, press button of the remote control 6.
Press button 5: Turn on all 6 relays
Press button 6: Turn off all 6 relays
 
How to pair the transmitter to the receiver:
1) Press the learning button of receiver for 1- 2 seconds; signal LED on the receiver is on. The receiver enters into status of LEARNING.
2) Press any one button on transmitter. If signal LED flashes quickly 15 times and turns off, it means learning is successful.
3) When receiver is in the status of LEARNING, press again the learning button, signal LED turns off, learning process will be discontinued.
4) The receiver can learn several remote controls with different codes.
 
Delete all transmitters:
We have learned remote control to the receiver. If you don’t want the receiver to work with the remote control, you can delete all codes of remote controls, which are stored in the receiver.
Operation: Press and hold the learning button of receiver until signal LED flashes slowly; release the button, LED keeps slow flash. That means all stored codes have been deleted successfully.
Ask A Question